This website stores cookies on your computer. These cookies are used to collect information about how you interact with our website and allow us to remember you. We use this information in order to improve and customize your browsing experience and for analytics and metrics about our visitors both on this website and other media. To find out more about the cookies we use,
see our Privacy Policy.

Open House • Learn how you can grow your career with us! • May 15 • 3:00–6:00 p.m. • Merrimack, NH
Tripp Lite SV Series Large-Frame Modular Scalable UPS System, 140KVA 208 120V, (8) Power Modules (SV140KL8P)
-
Temporarily Out-of-Stock
- Call for next available delivery
Ordering Information
Was
$80,885.38
$23,241.81 (28%)
Now
$57,643.57
Add to Cart
Messages
Loading
-
:
Quick View
Getting Details
The SV140KL8P SmartOnline SV Series 140kVA 3-Phase On-Line Double-Conversion UPS System delivers true scalability and offers the highest level of secure, uninterrupted power protection. Featuring a modular, scalable design with high-efficiency voltage and frequency independent (VFI) operation, this on-line UPS system is ideal for protecting a variety of critical IT systems.
The SV140KL8P includes preinstalled input, bypass and output breakers, as well as a static transfer switch (STS) and eight included 20kVA SV20PM power modules. The system is fully configured at 140kVA maximum capacity with N+1 fault tolerance. Each power module is rated at 0.9 power factor for maximum power to the connected load.
The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network.
With up to 92% efficiency in standard mode and up to 99% efficiency in optional economy mode, this 140kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Batteries are not included. External ±120VDC battery cabinets, such as Tripp Lite’s BP240V370, are sold separately.
The SV140KL8P includes preinstalled input, bypass and output breakers, as well as a static transfer switch (STS) and eight included 20kVA SV20PM power modules. The system is fully configured at 140kVA maximum capacity with N+1 fault tolerance. Each power module is rated at 0.9 power factor for maximum power to the connected load.
The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network.
With up to 92% efficiency in standard mode and up to 99% efficiency in optional economy mode, this 140kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Batteries are not included. External ±120VDC battery cabinets, such as Tripp Lite’s BP240V370, are sold separately.
-
514.37 lbs
-
140kVA 126kW 3-Phase Large-Chassis UPS System:
Supports 208/120V or 220/127V AC 50/60Hz Wye 4-wire plus Earth hardwire input and output wiring
Dual hardwire input design enables operation from up to 2 power sources
Network-grade sine-wave AC output with 1% output voltage regulation and less than 1.5% output total harmonic distortion
Tested to UL 1778 (U.S.), CSA (Canada) and NOM (Mexico) standards
High 0.9 power factor for maximum power to the connected load
Batteries not included—external ±120VDC battery cabinets, such as Tripp Lite’s BP240V370, sold separately
Pre-Installed WEBCARDLX Network Interface:
Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH
Supports 10/100 Mbps auto-sensing for communication with an Ethernet network
Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status
No Java required
Modular, Scalable Design for Maximum Flexibility:
Modular configuration with hot-swappable power modules enables easy and fast maintenance with zero downtime
Open slot for 1 additional 20kVA SV20PM power module for N+1 fault tolerance
Optional Economy Mode:
Up to 99% efficient in optional economy mode to lower operating and cooling costs
Wide Input/Narrow Output Voltage Operating Range:
Enables full continuous online operation during brownouts as low as 156V and overvoltages up to 253V
Regulates output voltage within 1% of the selected nominal output voltage in on-line double-conversion mode
Advanced IGBT Inverter with Digital Signal Processor (DSP) Technology:
Provides for less than 3% input total harmonic distortion (THDi) to support 1:1 generator sizing and prevent the need to oversize generator systems relative to UPS capacity
Automatic and Manual Bypass Options:
Keep connected equipment operational during routine maintenance or critical power module failure -
Communication Interface: Serial (RS-232)Connector: DB9Connector: Hardwire
-
UPS, pre-installed WEBCARDLX network interface, (8) SV20PM 20kVA power modules, documentation
-
Color: BlackForm Factor: ExternalForm Factor: TowerWarranty Period: 2 yearsWeight Taxonomy: 1209.99lbs
-
79.13"H x 23.62"W x 43.3"D
-
Communications Interface: DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface
Network Management Cards: WEBCARDLX
Network Monitoring Port Description: Includes pre-installed Tripp Lite WEBCARDLX network interface
PowerAlert Software: For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable: DB9 cabling included
SNMP Compatibility: Includes pre-installed WEBCARDLX network interface card
Front Panel LCD Display: 145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
Switches: Front panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
Alarm Cancel Operation: Audible alarms can be muted using on-screen prompts
Audible Alarm: Unique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)
LED Indicators: Front panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red) -
Power Capacity (VA): 14000VAPower Provided: 126kWPower Provided: 126000WSurge Suppression: StandardSurge Suppression: YesVoltage Provided: AC 120/127/208/220V
-
Communications Interface: DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface
Network Management Cards: WEBCARDLX
Network Monitoring Port Description: Includes pre-installed Tripp Lite WEBCARDLX network interface
PowerAlert Software: For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable: DB9 cabling included
SNMP Compatibility: Includes pre-installed WEBCARDLX network interface card
Front Panel LCD Display: 145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
Switches: Front panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
Alarm Cancel Operation: Audible alarms can be muted using on-screen prompts
Audible Alarm: Unique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)
LED Indicators: Front panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red)
Output Volt Amp Capacity (VA): 140000
Output kVA Capacity (kVA) : 140
Output Watt Capacity (Watts): 126000
Output kW Capacity (kW): 126
Output Capacity Details: OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
Power Factor: 0.9
Crest Factor: 3:1
Nominal Output Voltage(s) Supported : 120/208V 3-PH Wye; 127/220V 3-PH Wye
Nominal Voltage Details: Output THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: ±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included
Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details: Auto-selectable, user adjustable
Output Receptacles: Hardwire
Output Receptacle Details: Output wiring: 3P, N, E
Output Circuit Breakers: 630A 3 pole magnetic breaker
Output AC Waveform (AC Mode): Pure Sine wave
Output AC Waveform (Battery Mode): Pure Sine wave
Output Voltage Regulation:
ONLINE, FREQUENCY CONVERSION, BATTERY MODE: 208/120, 220/127 ±1% typical (balanced load); ±2% typical (unbalanced load); ECONOMY MODE: 208/120, 220/127 ±15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%)
Output Frequency Regulation:
ONLINE MODE: Output frequency is ±0.05Hz of input frequency when input is within ±4Hz* of the configured 50/60Hz output setting; Output frequency is ±0.05Hz the configured 50/60Hz output setting when input is outside ±4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to ±4Hz and is user adjustable to ±1Hz, ±2Hz or ±4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes
Output Amp -
Remote Management Protocol: HTTPRemote Management Protocol: HTTPSRemote Management Protocol: SNMP 1Remote Management Protocol: SNMP 2Remote Management Protocol: SNMP 3Remote Management Protocol: SSHRemote Management Protocol: Telnet
-
This product is subject to our return policy. Please see our complete return policy for details.
-
81.57 lbs
-
Compliant Standards: CSACompliant Standards: CSA C22.2 No. 107.3.14Compliant Standards: FCC Part 15 ACompliant Standards: NOMCompliant Standards: RoHSCompliant Standards: UL 1778Compliant Standards: UL 1778 5th edition
-
39121011
-
2 Years
-
2 Years
-
2-year limited warranty
Description | Availability | Unit Price | ||
---|---|---|---|---|
View All Warranties |
Batch Add Products by Item #
14