This website stores cookies on your computer. These cookies are used to collect information about how you interact with our website and allow us to remember you. We use this information in order to improve and customize your browsing experience and for analytics and metrics about our visitors both on this website and other media. To find out more about the cookies we use,
see our Privacy Policy.

Open House • Learn how you can grow your career with us! • May 15 • 3:00–6:00 p.m. • Merrimack, NH
Tripp Lite 1000VA UPS Smart Pro Tower Hospital Grade Extended Run Line-Interactive (4) Outlet (SMART1200XLHG)
-
Limited Quantity Available
- Call for next available delivery
Intelligent, line-interactive power management system
Ordering Information
Add to Cart
Messages
Loading
-
:
Quick View
Getting Details
Tripp Lite's SmartPro 1200XLHG offers medical-grade UPS protection with built-in line-interactive voltage regulation, expandable battery runtime and intelligent monitoring with unattended shutdown capability. This unit is UL 60601-1 listed as medical electrical equipment with less than 300 microamps leakage current for the UPS and all connected equipment. The built-in isolation transformer with Faraday shield offers full line isolation and removes common mode noise while maintaining full AC surge suppression in all modes.
The SmartPro 1200XLHG includes high quality hospital-grade plug and outlets and is resistant to electrostatic discharge. Its 1000VA power handling capacity supports computers, internetworking equipment and other critical loads during commercial power failures. An external battery connector allows configuration of up to several hours of runtime during power failures by adding one or more external battery packs (part# BP36V27). Line interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V back to normal 120V levels, saving battery reserves for use only during complete power failures.
Diagnostic LEDs and (2) built-in communications ports (1 USB, 1 DB-9) work with the included PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.
The SmartPro 1200XLHG includes high quality hospital-grade plug and outlets and is resistant to electrostatic discharge. Its 1000VA power handling capacity supports computers, internetworking equipment and other critical loads during commercial power failures. An external battery connector allows configuration of up to several hours of runtime during power failures by adding one or more external battery packs (part# BP36V27). Line interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V back to normal 120V levels, saving battery reserves for use only during complete power failures.
Diagnostic LEDs and (2) built-in communications ports (1 USB, 1 DB-9) work with the included PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.
-
45.20 lbs
-
LEDS ALARMS & SWITCHES
Front panel LEDs: (5) front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning
Alarms: 3-function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone)
Switches: (2) front panel mounted push-button switches for system enable, self-test and alarm cancel functions
SURGE / NOISE SUPPRESSION
AC surge suppression: 480 joules
AC suppression response time: Instantaneous
EMI / RFI AC noise suppression: Yes
COMMUNICATIONS
Network monitoring port: Includes (2) built-in monitoring ports, (1) USB, (1) DB-9
Software and cabling included: PowerAlert UPS monitoring software is included on CD-ROM for all common network and standalone operating systems. Ships with (2) cables, (1) USB to USB, (1) DB9 to DB9
LINE / BATTERY TRANSFER
Transfer time from line power to battery mode: 2-4 milliseconds
Low voltage transfer to battery power: 81V (resets to line power as voltage increases to 85V)
High voltage transfer to battery power: 143V (resets to line power as voltage decreases to 139V)
CERTIFICATIONS
Certifications: UL1778 (USA, Series AGSM1200PSR3HG), UL 60601-1 (Medical), cUL (Canada), Class A (Emissions) -
# Ports: 4Communication Interface: Serial (RS-232)Communication Interface: USBConnector: Power NEMA 5-15 (F)Connector: Power NEMA 5-15 (M)Connector: Power NEMA L5-15
-
UPS, software, cabling, documentation
-
Attributes: Line interactiveColor: BeigeColor: GrayEnclosure Type: InternalForm Factor: ExternalForm Factor: TowerWarranty Period: 2 yearsWeight Taxonomy: 46.08lbs
-
12.5"h x 7.5"w x 9.5"d
-
(4) NEMA 5-15R-HG Hospital-Grade outlets
(1) NEMA 5-15P-HG Hospital-Grade Input cord 6 ft., 14 AWG
(1) DB-9 RS-232 serial communications port
(1) USB communications port -
Battery Run Time (max): 16minPower Capacity (VA): 1000VAPower Provided: 750Power Provided: 750WSurge Suppression: StandardSurge Suppression: YesVoltage Provided: 120VVoltage Provided: AC 120V
-
Voltage compatibility: 120VAC
Frequency compatibility: 60Hz
OUTPUT
Output capacity: 750W/1000VA
Output nominal voltage: 120VAC
Output voltage regulation LINE MODE: Sine wave line voltage 120V (-18% / +8%)
Output voltage regulation BATTERY MODE: PWM sine wave output 115V +/-5%
Output frequency regulation LINE MODE: Passes line frequency of 60Hz +/-10%
Output frequency regulation BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz
Overload protection: Resettable circuit breaker
INPUT
Maximum input amps: 9.2A / 860 watts
Recommended electrical service: 15A, 120V
BATTERY
Full load runtime: 10 minutes (750W)
Half load runtime: 28 minutes (375W)
Expandable battery runtime: Supports extended runtime with optional BP36V27 external battery pack (multi-pack compatible)
DC system voltage: 36VDC
Typical battery lifespan: 3-6 years, depending on usage
Battery recharge rate: 2-4 hours to 90%
VOLTAGE REGULATION
Voltage regulation description: Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 81 to 143V AC.
Overvoltage correction: Input voltages between 126 and 143VAC are reduced by 9%
Direct pass through: Input voltages between 105 and 125VAC are passed through unchanged
Brownout correction: Input voltages between 96 and 106VAC are boosted by 10%
Severe brownout correction: Input voltages between 81 and 95VAC are boosted by 21% -
This product is subject to our return policy. Please see our complete return policy for details.
-
46.6 lbs
-
Compliant Standards: CULCompliant Standards: ULCompliant Standards: UL 1778
-
39121011