This website stores cookies on your computer. These cookies are used to collect information about how you interact with our website and allow us to remember you. We use this information in order to improve and customize your browsing experience and for analytics and metrics about our visitors both on this website and other media. To find out more about the cookies we use,
see our Privacy Policy.

Open House • Learn how you can grow your career with us! • May 15 • 3:00–6:00 p.m. • Merrimack, NH
CyberPower Switched ATS PDU 240V 2U (2) L6-30P Inputs 10ft Cords (16) C13 (2) C19 (1) L6-30R Outlets
-
Temporarily Out-of-Stock
- Call for next available delivery
Add to Cart
Messages
Loading
-
:
Quick View
Getting Details
The CyberPower PDU30SWHVT19ATNET, a 19-outlet 2U rack mount switched auto transfer switch (ATS) power distribution unit (PDU), provides 200-240V/30A output. The PDU distributes unfiltered electrical pass-through to (1) NEMA L6-30R, (18) IEC-320 [16) C13/(2) C19] receptacles from redundant NEMA L6-30P plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable.
The PDU30SWHVT19ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the ATS PDU. The switched outlet receptacles can be managed individually or collectively over the network using the CyberPower Management Console /web browser and the RJ-45 Ethernet port for network connection or locally, using the LCD controls.
Using the CyberPower Management Console, outlets can be turned on, turned off or recycled on demand or at programmed times to address multiple needs, including remote rebooting of locked equipment, load shedding, power sequencing and locking out unauthorized loads. Additionally, the CyberPower Management Console provides real-time remote monitoring of PDU vitals and event logging to review historical power conditions, such as input voltages, load levels and outlet status. Automatic event notifications can be sent to designated users when power events occur, via Email, SMS Text or SNMP Trap.
The LCD provides local monitoring of the PDU and on/off control the outlets. Perform load management by using the display to measure the electrical current (displayed in amperes) used by connected equipment. The LCD can also display input and output voltages, to diagnose potential issues with input AC power. Active power consumption (displayed in kilowatts) and hardware and firmware versions are also viewable on the LCD screen.
Designed for datacenters and other demanding electrical applications, the PDU20SWHVIEC10ATNET has a rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL60950-1 and CSA C22.2 certified by ETL and FCC Class A certified. A three-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.
The PDU30SWHVT19ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the ATS PDU. The switched outlet receptacles can be managed individually or collectively over the network using the CyberPower Management Console /web browser and the RJ-45 Ethernet port for network connection or locally, using the LCD controls.
Using the CyberPower Management Console, outlets can be turned on, turned off or recycled on demand or at programmed times to address multiple needs, including remote rebooting of locked equipment, load shedding, power sequencing and locking out unauthorized loads. Additionally, the CyberPower Management Console provides real-time remote monitoring of PDU vitals and event logging to review historical power conditions, such as input voltages, load levels and outlet status. Automatic event notifications can be sent to designated users when power events occur, via Email, SMS Text or SNMP Trap.
The LCD provides local monitoring of the PDU and on/off control the outlets. Perform load management by using the display to measure the electrical current (displayed in amperes) used by connected equipment. The LCD can also display input and output voltages, to diagnose potential issues with input AC power. Active power consumption (displayed in kilowatts) and hardware and firmware versions are also viewable on the LCD screen.
Designed for datacenters and other demanding electrical applications, the PDU20SWHVIEC10ATNET has a rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL60950-1 and CSA C22.2 certified by ETL and FCC Class A certified. A three-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.
-
16.76 lbs
-
Features & Benefits
Switched Power Distribution Unit (PDU) – 200-240VAC, 30A maximum capacity (derated to 24A) is distributed to connected equipment.
Outlet Switching – Output receptacles can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs including remote rebooting of locked equipment, load shedding, power sequencing and locking out unauthorized loads.
Automatic Transfer Switch (ATS) – Dual 10ft NEMA L6-30P power cords provide redundant power sources to devices with single power supplies.
Power Redundancy – A and B power cords can be plugged into separate power sources to ensure continuous power access. Users can select their preferred source as the primary input.
Power Distribution – One (1) NEMA L5-30R and eighteen (18) IEC-320 [(16) C13/(2) C19] outlets with unfiltered electrical pass-through are standard with the PDU30SWHVT19ATNET PDU.
LCD Display – The LCD provides real-time meter status for current (amperes), input and output voltages, power consumptions (kilowatts), and hardware/firmware versions.
SNMP/HTTP Card (RMCARD203) – A SNMP/HTTP Card provides outlet control, remote monitoring, reporting, and event notifications, via Email, SMS Text, or SNMP Trap. RMCARD203 firmware is upgradeable with FTP process.
Protocol Support – The switched ATS PDU includes protocol support for PowerPanel Business Edition, HTTP, TCP/IP, UDP, DHCP and SNMP including SNMPv3, IPv4, IPv6, NTP, SMTP protocols.
Administrative Rights – Administrator and user rights can be established to provide IT personnel with access to the Management Console via a web browser to monitor and/or manage the PDU settings.
Upgradeable Hardware and LCD Firmware – Hardware and LCD firmware can be updated to the latest versions using the serial communication port.
Serial Communication Port – The switched ATS PDU comes with a serial port and cable to update/upgrade the hardware and LCD firmware.
Environmental Sensor Option – Support for optional environment sensor (ENVIROSENSOR)
Rack Mountable – Included rack mounting brackets allow for 1U horizontal rack installation.
Cord Retention Brackets – Included cord retention brackets keep power cords organized and securely plugged in.
Switchless Design – Designed without a power switch and circuit breaker (on most models) to prevent accidental power interruptions. -
# Ports: 19Connector: Power IEC 320 EN 60320 C13 (F)Connector: Power IEC 320 EN 60320 C19 (F)Connector: Power NEMA L6-30Connector: Power NEMA L6-30 (F)Connector: Power NEMA L6-30 (M)
-
PDU, SNMP/HTTP card, mounting brackets, mounting screws, cable ties, serial cable, jumper, documentation
-
Attributes: MeteredAttributes: SwitchedColor: BlackForm Factor: 1U RackmountForm Factor: Rack-mountableWarranty Period: 3 years
-
1.75"h x 17.1"w x 9.3"d
-
Connectors
Plug Type: (2) NEMA L6-30P
Plug Style: Straight
Cord Length: 10ft
Outlets - # of Banks: (2)
Outlets - Total: (19)
Outlet Type: IEC-320 C13 (16)/C19 (2), NEMA L6-30R (1)
Outlets - Rear: (19)
Display
LCD Readout: KW, Voltage, Amperage, Network Information, HW/FW Version
LED Indicators: Input, Output Load, Tx/Rx, LINK, Outlets
Management & Communications
SNMP / HTTP Remote Monitoring: RMCARD203 (Installed)
Protocols: TCP/IP, UDP, DHCP, SNMP, HTTP
Connectivity: Network, Environmental Sensor, Serial -
Voltage Provided: 120VVoltage Provided: AC 200-240V
-
Input
Voltage: 200Vac - 240Vac
Overload Protection (Each Bank): 20A
Frequency: 50Hz/60Hz
Maximum Input Current: 30A (Derated to 24A)
On/Off Switch: No
Output
Nominal Output Voltage: 200V - 240Vac -
Remote Management Protocol: HTTPRemote Management Protocol: SNMP
-
This product is subject to our return policy. Please see our complete return policy for details.
-
20.06 lbs
-
Compliant Standards: CSA 22.2Compliant Standards: CSA C22.2Compliant Standards: ETLCompliant Standards: FCC Class A certifiedCompliant Standards: RoHSCompliant Standards: UL 60950-1
-
39121017
-
3 Years
-
3 Years